Technical Data












Model

Max.

PV  Power

[W]

Nominal

DC

Power [W]

Max.

DC Current

[A] 


Max.

Short Current [A]

No. of

DC

Connectors

Norminal

AC Power

[W]

Max.

AC Current

[A]













GW50K-MT650005150030/30/20/20
37.5/37.5/25/2510(3/3/2/2)5000080
GW60K-MT750006200030/30/30/30
37.5/37.5/37.5/37.512(3/3/3/3)6000096
GW75KHV-MT80000
75000
28/28/28/36

35/35/35/4512(3/3/3/4)75000
90

Model

Max. AC

Power [W]

Max. AC

Apparent Power [W]

Max.

Efficiency


Euro

Efficiency

MPPT Adaptation

Efficiency

Dimensions

(WxHxD)

Weight

(kg)













GW50K-MT

55000@400Vac,

57500@415Vac

55000@400Vac,

57500@415Vac

98.70%
98.30%99.90%586*788*264mm59kg












GW60K-MT

66000@400Vac,

69000@415Vac

66000@400Vac,

69000@415Vac

98.80%
98.50%99.90%586*788*264mm64kg












GW75KHV-MT

66000@400Vac,

69000@41

66000@400Vac,

69000@415Vac

98.8%

98.5%
99.9%
586*915*263mm
67kg

point.pngDC Input Data
point.pngAC Output Data


Max. DC Voltage [V]
1000

Norminal AC Output50/60Hz; 400Vac

MPPT Voltage Range [V]
200~850

AC Output Range45~55Hz/55~65Hz;310~480Vac

MPPT Voltage Range of   Full Load [V]
520~850

THDi<3%

Nominal DC Voltage
620

Power Factor~1(Adjustable from 0.80leading to 0.80lagging)

Starting Voltage [V]
200

Grid Connection3L/N/PE

No. of MPPT
4




DC Connector
MC4/Phoenix/Amphenol




point.pngProtection
point.pngGeneral Data


Residual Current   Monitoring Unit
Integrated

MountingWall bracket

Anti-islanding Protection
Integrated

Ambient Temperature Range-30~60°C

Pv Array String Fault Monitoring
Integrated

Relative Humidity0~100%

DC Fuse
Integrated

Operating Altitude(m)4000

DC Switch
Integrated (optional)

Protection DegreeIP65

DC SPD
Type II

TopologyTransformerless

AC SPD
Type II

CoolingFan cooling

SPD Fault Monitoring
Integrated

DisplayLCD

AC Over Curent Protection
Integrated

CommunicationRS485; WiFi

Insulation Monitoring
Integrated

Standard Warranty(years)5/10/15/20/25(optional

point.pngCertifications & Standards


Grid regulationVDE0126-1-1, AS4777.2, G59/3, VDE-AR-N 4105,   EN50438, EC61727, IEC62116, PV502

SafetyEN62109-1&-2

EMCEN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4


تحميل المواصفات